Sizing a battery pack for a converted car

Most people size their first pack backwards. They find a good price on a pallet of cells, buy as many as the budget allows, and then try to work out what voltage and range that gives them. It sometimes works. More often it gives you a pack that is too low in voltage for the controller you wanted, or that cannot supply the current your motor asks for without sagging into the floor.

Sizing a pack properly is three separate calculations, energy, voltage and power, followed by a fourth one that usually overrules the other three, which is where it physically fits and what it weighs.

Energy from honest consumption figures

Energy is range multiplied by consumption. The range part is easy. Decide what distance you genuinely need between charges, not the trip you take twice a year. The consumption part is where people fool themselves, because the efficiency figures quoted for factory electric cars come from slippery bodies, low rolling resistance tyres and integrated thermal management that your 1970s coupe or old hatchback does not have.

The best number is one you measured. If you know someone with a similar converted car, ask what their BMS logged. My coupe, which is not aerodynamic by any standard, uses somewhere around 170 to 200 Wh per kilometre in electric mode on country roads according to its own shunt, and noticeably more on the motorway or with the heater running. Use your own car’s shape, weight and speed profile, and when in doubt round up.

Then plan to use only part of the pack. I design around roughly 80 percent of nameplate capacity as the usable window. That leaves headroom at the top so regenerative braking has somewhere to go, keeps the cells away from the bottom of the curve where voltage collapses, and gives you some margin for cold weather and ageing. The general background on depth of discharge is worth reading if the idea is new to you.

So a car that needs 60 km of real range at 180 Wh/km needs about 10.8 kWh usable, which means roughly 13.5 kWh of nameplate capacity. That is the energy target. It says nothing yet about how the cells are arranged.

Voltage is decided by the controller, and by your training

The pack voltage has to suit the motor controller, and you check that at both ends of the charge. A LiFePO4 cell sits around 3.2 V nominal, reaches 3.65 V at full charge, and should not be taken much below 2.5 V. Multiply by your series cell count and compare the full charge figure with the controller’s absolute maximum input voltage, and the empty figure with its undervoltage cutout. A 32 cell series pack is 102.4 V nominal but 116.8 V when full, and regenerative braking on a full pack can push it briefly higher still. A controller sold as a 96 V unit may not tolerate that.

Higher voltage means less current for the same power, which means thinner cables, smaller contactors and less heat. That is why factory cars run at 300 V or more. It is also why I keep telling first time builders to stay below 60 V DC. Below that threshold a pack can still start a fire or burn you badly through a short, but it is far less likely to drive a fatal current through your body. Above it you need insulated tools, rated gloves, proper isolation monitoring and real training. If you do not have those, choose the lower voltage and accept the heavier cables. Article 08 on this site goes through high voltage wiring in detail.

Power and the current your cells can deliver

Peak power is what gives you the acceleration and hill climbing you want, and current is how the pack delivers it. Divide the peak power by the pack voltage under load, not the nominal voltage, because the pack sags when you pull hard. Then compare that current with what each cell is rated to supply continuously and for short bursts, which is on the datasheet as a multiple of capacity, called the C rate.

Here is how the same peak demand of 30 kW looks across three plausible LiFePO4 layouts, calculated at nominal voltage for simplicity.

Layout Nominal voltage Nameplate energy Current at 30 kW As a C rate
32 cells of 100 Ah in series 102.4 V 10.2 kWh about 293 A about 2.9C
32 cells of 280 Ah in series 102.4 V 28.7 kWh about 293 A about 1.05C
96 cells of 100 Ah in series 307.2 V 30.7 kWh about 98 A about 1C

The first layout is the trap. On paper it gives you 10 kWh, which looks like enough, but asking a 100 Ah cell for nearly 3C will exceed many datasheets’ continuous rating and cause heavy sag and heat. The other two layouts deliver the same power comfortably, one by having bigger cells and one by having higher voltage. Neither is free. The 280 Ah pack weighs far more. The 96 cell pack is a genuinely dangerous high voltage system.

For a parallel hybrid, which is what my coupe is, the balance shifts. The engine covers long distances, so the pack is sized more for power than for range. That pushes you towards cells with a good continuous discharge rating and a moderate energy total, rather than the biggest pack you can fit.

Space, weight and the things you forget

Now the reality check. Work out the physical volume of your cells with compression end plates, busbars, BMS boards and at least a few centimetres of air gap and cable routing. Then compare it with the spaces you measured in the car. A 100 Ah prismatic cell weighs roughly two kilos, so every 32 cell group is in the region of 65 kg before the enclosure. Add the box, the fixings and the cabling and check the axle loads again against the plate.

Splitting the pack into several modules helps packaging and helps safety. I build modules that stay below 60 V each and only join them in series at the very end, through the service disconnect. Every time I work on the pack I can take it apart into pieces that will not kill me.

Things that quietly eat energy and get left out of the sums:

  • The DC to DC converter feeding the 12 V system, which runs lights, fans, pumps and wipers continuously.
  • The cabin heater, which in winter can draw several kilowatts on its own.
  • The vacuum pump and power steering pump if they are electric.
  • Pack heating, if you fit pads to keep the cells above freezing for charging.
  • The BMS itself, which draws a small current permanently and will drain a parked pack over months.

The charger also has to match. Its output voltage range must cover your pack from empty to full, and its current should be well within the cells’ charge rating. Check that before you order cells, not after.

Finally, check the energy against what your battery management system and charger can actually report and limit. A pack you cannot monitor at cell level is a pack you are guessing about, and guessing about lithium is how garages burn down. The overview of electric vehicle batteries gives useful context on how factory packs handle these same trade offs at much larger scale.