I am going to start this one with a warning instead of a story, because the story version of this warning is someone’s funeral. A traction pack above 60 V DC can kill you, and a pack of any voltage with large cells can deliver short circuit currents that vaporise metal and set fire to a garage. If you have not been trained in live electrical work and you do not own properly rated protective equipment, do not build or wire a high voltage pack. Build at 48 V, or have a qualified person build and commission the high voltage side for you.
What follows is how I approach high voltage work in my own garage. It is a description of good practice, not a training course, and it does not replace one.
Before anything touches the pack
The equipment comes first, and none of it is optional above 60 V.
- Insulating gloves rated for the voltage. Class 0 gloves are rated for 1000 V AC and 1500 V DC working voltage. Wear leather protectors over them, air test them for pinholes every time before use, and have them dielectrically retested on the schedule the standard requires.
- A full set of insulated tools rated to 1000 V, including spanners and a torque wrench with insulated extensions.
- A multimeter with a measurement category and voltage rating above your full pack voltage, with probes and leads to match.
- A face shield over safety glasses. An arc throws molten copper.
- A rubber insulating mat under you and a clear, dry bench around you.
- A suitable fire extinguisher by the door and a second person nearby who knows how to cut power and call for help.
Remove rings, watches and metal bracelets before you start. A wedding ring across two terminals heats up faster than you can get it off, and the burns are terrible. Work with one hand where you can, keeping the other away from the pack and the chassis, so that a fault current does not have a path across your chest. The arc flash and electrical injury articles are worth reading before you start, not after.
Build it in pieces that cannot hurt you
The most important design decision for safe assembly is to split the pack into modules that each stay below 60 V, and to keep them separated until the very end. On my coupe that is four modules of eight LiFePO4 cells each, about 25.6 V per module, joined in series only through the inter module links and a service disconnect plug.
Build each module on the bench with insulating caps over every terminal you are not working on. Connect busbars one at a time, torque them to the cell manufacturer’s figure, and mark each nut with a paint pen once it is torqued so you can see at a glance which ones are done. Never leave a busbar lying loose across a module. Never put a metal tool down on top of a pack, even for a moment.
Fit the modules into the enclosure individually. Run the inter module cables with their far ends left disconnected and insulated. Make the final series connections last, and leave the service disconnect out until everything else is finished, inspected and tested. With the disconnect pulled, the pack is broken in the middle and no part of it carries the full voltage.
Cables, lugs, fuses and contactors
Size the cable from the manufacturer’s rating table for your continuous current, insulation temperature rating and how the cables are bundled, then go up a size. My 102 V pack with a controller limited to around 300 A peak runs on 50 mm² flexible double insulated cable in orange, which is the conventional colour for high voltage in vehicles and tells anyone who works on the car what they are looking at.
Crimp lugs properly. That means tinned copper lugs matched to the cable size, a hydraulic crimper with the correct hex die, and adhesive lined heat shrink over the barrel. Pull test every crimp by hand. A lug squashed with a hammer crimper or a vice looks fine and then heats up under load until the insulation melts. I have cut open bad crimps from other people’s builds and found them blackened inside.
The main fuse is your short circuit protection, and it must be rated for DC at above your maximum pack voltage, with an interrupting rating comfortably above the prospective short circuit current the cells can deliver. A fuse rated only for AC, or for 32 V automotive use, may not break a DC arc at all. Size the current rating to protect the cable, and place the fuse as close to the cells as practical. Many builders put it in the middle of the pack alongside the service disconnect so it protects both halves.
Use DC rated contactors on both the positive and negative legs, so that opening them fully isolates the pack from everything downstream. Check whether your contactors are polarity sensitive. Many DC contactors use magnets to blow the arc out and only work properly with current in one direction. Fit a precharge circuit, a resistor and small relay that charges the controller capacitors slowly before the main contactor closes. Without it the inrush current can weld the contactor shut, and a welded contactor is a contactor that can no longer protect you.
Routing, isolation and the first power up
Keep high voltage wiring physically separate from the 12 V loom, in its own conduit or clipped on its own path. Use rubber grommets or cable glands everywhere a cable passes through metal, support it with clips at regular intervals so it cannot vibrate against an edge, and keep it well clear of the exhaust and any moving suspension parts. A cable that chafes through in five years is a fault you are designing in today.
The traction pack must float, with no connection between either pack leg and the chassis. Metal enclosures and the controller case are bonded to the chassis, but the high voltage conductors are not. Fit an isolation monitor that warns you if insulation resistance between the pack and the chassis falls. Insulation resistance testing with a dedicated tester at the appropriate test voltage is part of commissioning, and it is one more reason this work belongs with someone trained.
Before the first energising, I go round every connection with the paint pen marks, check polarity at the contactors with the pack still split, confirm the precharge resistor is correctly rated, and make sure the emergency stop opens the contactors. Then, with the gloves on and the second person standing by, the service disconnect goes in last. If anything smells, clicks unexpectedly or reads wrong, it comes straight back out.
None of this is fast. It is not meant to be. Rushing is how people get hurt.